GCE Medical products now found on gce-medical.com FIND OUT MORE close
Home » RD 05 - RELEASE SECURITY SYSTEM

RD 05 - RELEASE SECURITY SYSTEM

Because some fluid in a network can be dangerous, GCE has developped an efficient security device that will act on the flow when the outlet pressure will be very high or very low.


The GCE security device is used only with selected regulators of the range. The security valve cut the inlet gas flow, if the outlet pressure is out of the pressure slot that has been previously adjusted.

TECHNICAL DATA

Spring pressure slot:  

   RD05 C:


0,3-0,8 bar                                        l290813
Mini adjustment 0,2 to 0,4 bar
Maxi adjustment 0,3 to 1,2 bar

   RD05 B1:


0,5 to 2 bar                                       l290814
Mini adjustment 0,3 to 1,3 bar
Maxi adjustment 0,7 to 3 bar

   RD05 B2:

0,5 to 2 bar                                        l290816
Maxi adjustment 0,7 to 3 bar

   RD05 A:


1,3 to 5 bar                                        l290815
Mini adjustment 0,6 to 3 bar
Maxi adjustment 1,6 to 6,7 bar

Valve reaction time: < 1 second (norm < 2 seconds)
Release precision: Class AG 5 for pressure < 0,5 bar
  Class AG 2,5 for pressure between 0,5 and 6 bar
Definition: class of precision: AG 2,5 means that as soon as the security is adjusted at 1 bar, it is
released between 0,975-1,025 bar. (±2,5%). It is the same for AG 5 class (±5%)
Operating temperature range: from -20 to + 60°C
Technical Drawings Top

Download Technical Drawings