MEDIUNIT SS TYPE

Whole medical range is available on gcehealthcare.com Medical terminal units provide a quick and easy connection of hospital ward gas equipment to the hospital gas source. The type of medical gas outlets are decided by national standards in each country and sometimes from local requests in each hospital. GCE complies with ISO 7396 and national installation standards with secure products where every product is fully tested in production. Our Medi

FMD 522/562 DUAL STAGE REGULATOR 6.0 INERT

These pressure regulator consists of a cylinder connection, pressure regulator body, upstream and downstream pressure gauges, diaphragm shut-off valve MVA 500 (only type-16), regulating valve MVR 500 (Type -18), relief valve and outlet tube fittings. The use of contact gauge (accessories) in conjunction with alarm box (accessories) facilitates the monitoring of gas reserves. SPECIAL FEATURES For low downstream pressure Subatmospheric-pressur

FLEXIBLE HOSES - Stainless steel

Stainless steel corrugated hoses with the pre-assembled cylinder valve adaptor. Working pressure up to 300 bar. Robust design according to ISO 10380. The high pressure corrugated hose consists from two ends (DN6). The inlet is equipped with pre-assembled cylinder valve adaptor according to national standard, outlet connection for DN6 has W21,8 for air gases and CO2, W21,8LH for flammable gases. Corrugated hose is covered by stainless steel braid

MEDICOLLECT

Whole medical range is available on gcehealthcare.com COLLECTING SYSTEM   GCE MediCollect and its accessories is intended for collection of liquids or/and solid particles or/and gas from body cavities or wound. It is intended to be used by healhcare professionals.  GCE Medicollect range includes different sizes of jars. The collecting systems are air-tight, autoclavable and fitted with overfill protection. FEATURES AND BENEFITS E

DIAPHRAGM REGULATING VALVES MVR-A 500 G

The regulating valve MVR-A 500 has a very good regulating characteristic and is very finely adjustable both by greater as also by lesser flow rate values. APPLICATION As a system component in and low pressure areas. As accessory for cylinder and point-of-use regulators for fine adjustment of the gas flow. As system element in apparatus and analytical equipment. Very fine gas flow adjustment Wide flow rate range for high and low pressure app

OUTLET POINTS UNISET

UNISET are new outlet points in GCE’s proposal for industrial gases service. They were created using the long term experience with production of central gas supply systems. Variants for oxygen and fuel gases are equipped with three function flashback arrestors (FBA). There are two design types for shielding gases. The first consists of flow-gauge showing flow-rate adjusted by a pressure regulator. The second one is based on a flow-meter wit

LINE REGULATOR

Whole medical range is available on gcehealthcare.com A stabilizer is a pressure reduction unit with the task to equalize the eventual pressure variation in the hospital pipeline system to ensure a correct pressure from the terminal units.The stabilizer makes it possible to distribute gas with different pressure to department and buildings in the hospital area. In some cases it is needed to deliver a higher pressure from the main gas manifold to

GAS MANIFOLD MC80 - STABILIZER

Whole medical range is available on gcehealthcare.com Manifold MC80 – STABILIZER is a second stage pressure reduction unit with the task to equalize the eventual pressure variation in the hospital pipeline system to ensure a correct pressure from the terminal units. MC80 – STABILIZER is only second stage reduction unit where the primary gas supply is provided by high pressure gas manifolds (such as MC80, MM90 or liquid oxygen tank (L

CHECK VALVES

Art. Nr. Material H45002060 SS/ FKM H03882603 Brass/ Buna H03882601 SS/ Viton B000638 SS/ FKM B000727 SS/ EPDM FOR MORE INFORMATION SEE DATASHEETS.

POINT-OF USE REGULATOR EMD 404 STANDARD

Standard version regulator with gauge, inlet at rear, outlet downwards. May be combined with inlet shut-off valve  MVA 400, wall connector, metering valve MVR 400G and MVR 400W, different gauges and diverse accessory (see  previous pages). APPLICATION For wall, plate, suspended and bench mounting, with great variety of combinations, covering any laboratory gas supply demand. ECD-suitable Great variety of assembly possibilities in